Product Detail G515

GUBAILI G515 Formed-in-Place Anaerobic Flange Sealant

GUBAILI G515 one-component anaerobic flange sealant: purple gel, fills gaps up to 0.25 mm, flexible bond line, UV fluorescence for quality inspection. For steel and aluminum flanges on pumps, compressors, gearboxes and axle covers. 50 ml/300 ml.

Thixotropic

Non-sagging at rest, flows under shear for easy application.

Corrosion Resistance

Resists acids, alkalis, solvents and other media.

Sealing

Forms a tight seal against gas and liquid leakage.

Anti-Loosening

Effectively prevents thread loosening.

Product Parameters

Technical Parameters
ParameterSpecification / Value
Product TypeGasket sealant
ChemistryMethyl acrylate
Cure SystemAcrylate anaerobic curing
ComponentsOne-component
FormGel
ColorPurple
Strength LevelMedium strength
Viscosity (25°C)150000 ~ 375000 mPa·s (cP) (also available 700000 ~ 1700000 mPa·s)
Maximum Gap Fill0.25 mm (0.01 in.)
Initial Set Time30 minutes
Laboratory Shear Strength6.0 N/mm²
Storage Temperature8°C ~ 21°C
FeaturesThixotropic, fluorescent for inspection, flexes with minor flange movement
Recommended SubstratesSteel, aluminum
Packaging50 ml / 300 ml

Product Details

Product Introduction

Product Overview

GUBAILI G515 is a one-component acrylate anaerobic flange sealant. The adhesive is a purple gel with built-in thixotropy that resists run-off after application, suitable for manual and automated dispensing. It cures anaerobically, crosslinking only in tightly fitted metal joints isolated from oxygen, forming a low-pressure seal once assembled and tightened. The bond line has some flexibility, allowing it to flex with minor flange movement without cracking. It fills gaps up to 0.25 mm, compensating for minor machining scratches and flatness errors. The product fluoresces under UV light, making the seal line visible for visual inspection and traceability of application completeness—ideal for quality control in volume production—and widely replaces conventional rubber or paper gaskets.

Industries

Typically used in construction machinery, automotive drivetrains and fluid pumps and valves. Typical applications include flat-face sealing of rigid metal flanges such as pump bodies, thermostats, compressors, gearbox housings and axle covers, on machined steel and aluminum substrates.

Instructions

1. Clean the flange mating surface, thoroughly removing old gasket residue, oil and machining dust, and keep it dry and clean;
2. Apply a continuous, uniform closed-loop bead along the sealing path, manually or with automated dispensing equipment;
3. Align and join the parts and tighten the bolts so the flange fits tightly; the confined environment triggers anaerobic curing;
4. Initial set takes about 30 minutes at 25°C, after which the part can be moved; allow full cure before pressure service;
5. Wipe uncured squeeze-out with anhydrous ethanol; cure the bond line and separate flanges by mechanical disassembly or localized heating.

Precautions

1. Store at 8-21°C in a cool, dark place; high temperature shortens shelf life;
2. Only suitable for sealing rigid metal flanges; porous materials and wide-open gaps cannot exclude air and will not cure properly;
3. Work in a ventilated area and wear protective gloves to avoid contact with skin and eyes;
4. Do not exceed a seal gap of 0.25 mm; excessive gaps can cause poor curing and leakage;
5. Fluorescence inspection requires a UV light source and is only for seal-line inspection; it does not change sealing performance;
6. Industrial adhesive—keep away from children and do not ingest.

FAQ

FAQ
How should flange surfaces be prepared before applying sealant?

Degrease, derust and remove old sealant and burrs from the flange face, and keep it dry. Apply a continuous closed bead, keeping clear of the inside of bolt holes and leaving bolt passages open.

After assembly, tighten in stages in a diagonal sequence to the specified torque, avoiding squeezing the sealant out on one side and creating an interruption in the seal.

Are sealants resistant to temperature and oil, and how are they disassembled?

Anaerobic types suit medium-to-high temperature sealing of rigid structures, while silicone types cover a wider temperature range and remain flexible. For oil contact, select an oil-resistant grade based on the media. Refer to the data sheet for specific temperatures.

To disassemble, separate the flange first, then remove residual sealant with a scraper or dedicated cleaner without scratching the sealing face; leftover sealant will impair the next seal.

For flange sealing, should I choose anaerobic or silicone?

For rigid flanges requiring immediate pressure resistance and high temperature performance, prefer anaerobic types such as G510 and G515; for stamped sheet metal, uneven gaps or slightly distorted flanges, choose semi-flexible G518.

For high temperature or a wider temperature range, choose silicone types G596 and G598; for oil contact, prefer G5699; to replace conventional gaskets, choose G587.

How is G515 flange sealant used?

For flat-face sealing of rigid flanges such as reducers and pump bodies, replacing conventional gaskets.

Remove old gasket and oil before application, and tighten bolts in stages in a diagonal sequence.

Related Products

More Structural & Sealant Adhesives Options

Need a formulation matched to your application?

We customise formulations by substrate, viscosity, cure speed and media resistance, and provide sample testing and technical selection support.

Custom Bonding Solutions

Need adhesive selection advice or sample testing?

Tell us about your application and our engineers will provide product recommendations, sample dispatch and technical support within 48 hours.

×