GUBAILI G577 one-component medium-strength anaerobic thread sealant: yellow thixotropic paste, tolerates light oil, suitable for straight and tapered metal pipe threads, stainless steel friendly, service temperature -55 to 150°C. 50 ml/250 ml.
Non-sagging at rest, flows under shear for easy application.
Stable performance over a wide temperature range.
Resists acids, alkalis, solvents and other media.
Forms a tight seal against gas and liquid leakage.
| Parameter | Specification / Value |
|---|---|
| Product Type | Thread sealant |
| Chemistry | Acrylate |
| Cure System | Acrylate, anaerobic curing |
| Components | One-component |
| Form | Paste |
| Color | Yellow |
| Strength Level | Medium strength |
| Viscosity (20 RPM) | 25000 mPa·s (cP) |
| Maximum Gap Fill | 0.25 mm (0.01 in.) |
| Breakaway Torque (Steel M10) | 33.0 N·m (295.0 in./lb.) |
| Service Temperature Range | -55°C ~ 150°C |
| Features | Thixotropic, chemical resistant, fluorescent for inspection, tolerates light contamination, high-temperature capable |
| Recommended Substrates | Active and passive metals, stainless steel, tapered threads |
| Packaging | 50 ml / 250 ml |
Product Overview
GUBAILI G577 is a one-component, medium-strength thixotropic anaerobic thread sealant. The adhesive is a yellow paste with excellent thixotropy that resists run-off after application, suitable for manual and automated dispensing. Developed specifically for metal pipes and threaded fittings, it provides both threadlocking and sealing and works with straight-to-straight and straight-to-tapered thread configurations. It forms an immediate low-pressure seal after assembly and tightening; the cured sealant does not creep, shrink or crack, ensuring durable sealing. No primer is required, and it performs well on passive metals such as stainless steel. It has outstanding contamination tolerance, curing normally with light oil such as machining oil, lubricating oil or rust-preventive oil on the surface, and fills gaps up to 0.25 mm. The cured sealant has excellent chemical resistance and fluoresces under UV light for seal-line inspection. Its medium strength makes later maintenance disassembly easier.
Industries
Widely used in hydraulic, pneumatic, water supply and drainage, and oil and gas piping for sealing and locking metal threads, including straight and tapered pipe fittings, stainless steel lines and standard carbon steel lines.
Instructions
1. Clean the threads first, removing heavy oil, metal chips and old sealant residue; light oil is tolerated, but heavy contamination should be cleaned and dried first;
2. Apply adhesive evenly over the thread engagement area, fully covering the engaged threads;
3. Tighten the fitting to the specified torque so the threads engage tightly and exclude air, triggering anaerobic curing;
4. After initial set the joint can withstand low pressure; full cure provides maximum sealing and locking strength;
5. Wipe uncured squeeze-out with anhydrous ethanol; medium strength allows disassembly with tools during maintenance.
Precautions
1. Anaerobic curing system—only suitable for tightly engaged metal threads; non-metallic or open gaps will not cure properly;
2. Work in a ventilated area and wear protective gloves to avoid contact with skin and eyes;
3. Do not exceed a seal gap of 0.25 mm; excessive gaps cause poor curing and leakage;
4. Fluorescence is only for visual seal-line inspection and does not change sealing or locking performance;
5. Industrial adhesive—keep away from children and do not ingest.
Degrease, derust and remove old sealant and burrs from the flange face, and keep it dry. Apply a continuous closed bead, keeping clear of the inside of bolt holes and leaving bolt passages open.
After assembly, tighten in stages in a diagonal sequence to the specified torque, avoiding squeezing the sealant out on one side and creating an interruption in the seal.
Anaerobic types suit medium-to-high temperature sealing of rigid structures, while silicone types cover a wider temperature range and remain flexible. For oil contact, select an oil-resistant grade based on the media. Refer to the data sheet for specific temperatures.
To disassemble, separate the flange first, then remove residual sealant with a scraper or dedicated cleaner without scratching the sealing face; leftover sealant will impair the next seal.
For rigid flanges requiring immediate pressure resistance and high temperature performance, prefer anaerobic types such as G510 and G515; for stamped sheet metal, uneven gaps or slightly distorted flanges, choose semi-flexible G518.
For high temperature or a wider temperature range, choose silicone types G596 and G598; for oil contact, prefer G5699; to replace conventional gaskets, choose G587.
For thread sealing of metal pipe fittings, covering common media such as water, gas and oil.
Threads must be clean and dry; apply adhesive over the engagement length, tighten, allow to cure, and then pressurize.
We customise formulations by substrate, viscosity, cure speed and media resistance, and provide sample testing and technical selection support.
Tell us about your application and our engineers will provide product recommendations, sample dispatch and technical support within 48 hours.