Product Detail G596

GUBAILI G596 High-Temperature One-Component Silicone Rubber Sealant

GUBAILI G596 one-component red RTV silicone rubber sealant: acetic-cure moisture curing, long-term temperature resistance 316°C, oil and fire resistant, maximum gap fill 6 mm. For blast furnaces and boilers, electronic encapsulation and automotive powertrain sealing. 300 ml.

High Viscosity

High consistency that resists run-off, ideal for filling large gaps.

High/Low Temp Resistance

Stable performance over a wide temperature range.

Flexible

Flexible and elastic after cure, accommodating movement and vibration.

Sealing

Forms a tight seal against gas and liquid leakage.

Product Parameters

Technical Parameters
ParameterSpecification / Value
Product TypeSilicone sealant (RTV silicone rubber)
Cure MethodAcetic-cure room-temperature vulcanization
ComponentsOne-component
ColorRed paste
Density1.02 ~ 1.45 g/cm³
Hardness (Shore A)A18 ~ A36
Surface Tack-Free Time45 minutes
Full Cure Time24 hours (room temperature)
Working Time15 ~ 30 minutes (varies with environment)
Extrusion Rate>= 250 g/min
Elongation at Break>= 300%
Service Temperature Range-55°C ~ 316°C
Maximum Gap Fill6 mm
Shelf Life12 months
Recommended SubstratesMetals, glass, plastics, electronic components
Packaging300 ml

Product Details

Product Introduction

Product Overview

GUBAILI G596 is a one-component acetic-cure room-temperature-vulcanizing (RTV) silicone rubber sealant. The adhesive is a red paste that requires no mixing and cures by crosslinking with moisture in the air. It forms a highly flexible silicone rubber seal with oil and fire resistance and outstanding high-temperature performance—long-term service temperature up to 316°C—suitable for extreme high-temperature conditions. It fills large gaps up to 6 mm and follows substrate deformation well; elongation at break is at least 300%, so it resists cracking and debonding under thermal cycling. It bonds and seals metals, glass, some plastics and electronic components, making it suitable for high-temperature equipment repair, electronic encapsulation, automotive powertrains and high-temperature machinery OEM assembly.

Industries

Industrial high-temperature equipment: blast furnaces, ovens and boilers for sealing and repair; electronic component encapsulation and sealing; automotive powertrain flat-face sealing; assembly and fixing of high-temperature mechanical parts; bonding and sealing of dissimilar materials such as metal, glass and plastic.

Instructions

1. Thoroughly clean the bonding and sealing surfaces, removing oil, dust and old adhesive residue, and keep the substrate dry and clean;
2. Apply evenly with a caulking gun and assemble quickly after application; working time is 15-30 minutes;
3. Surface tack-free in about 45 minutes at room temperature; full cure in 24 hours; curing slows in low-temperature, low-humidity conditions;
4. Wipe uncured squeeze-out with anhydrous ethanol; the cured bond line is tough and can be removed by mechanical cutting or sanding.

Precautions

1. This is an acetic-cure silicone rubber that releases acetic acid during curing; test compatibility with corrosion-sensitive metals and sensitive electronics beforehand;
2. Moisture-curing system—thick bond lines cure slowly inside; for large gaps, apply in stages;
3. Work in a ventilated area and wear protective gloves to avoid contact with skin and eyes;
4. Do not exceed a seal gap of 6 mm; exceeding the fill limit affects sealing performance;
5. Shelf life 12 months in cool conditions; keep sealed and away from heat;
6. Industrial adhesive—keep away from children and do not ingest.

FAQ

FAQ
How should flange surfaces be prepared before applying sealant?

Degrease, derust and remove old sealant and burrs from the flange face, and keep it dry. Apply a continuous closed bead, keeping clear of the inside of bolt holes and leaving bolt passages open.

After assembly, tighten in stages in a diagonal sequence to the specified torque, avoiding squeezing the sealant out on one side and creating an interruption in the seal.

Are sealants resistant to temperature and oil, and how are they disassembled?

Anaerobic types suit medium-to-high temperature sealing of rigid structures, while silicone types cover a wider temperature range and remain flexible. For oil contact, select an oil-resistant grade based on the media. Refer to the data sheet for specific temperatures.

To disassemble, separate the flange first, then remove residual sealant with a scraper or dedicated cleaner without scratching the sealing face; leftover sealant will impair the next seal.

For flange sealing, should I choose anaerobic or silicone?

For rigid flanges requiring immediate pressure resistance and high temperature performance, prefer anaerobic types such as G510 and G515; for stamped sheet metal, uneven gaps or slightly distorted flanges, choose semi-flexible G518.

For high temperature or a wider temperature range, choose silicone types G596 and G598; for oil contact, prefer G5699; to replace conventional gaskets, choose G587.

What locations suit high-temperature G596 silicone rubber?

A one-component high-temperature silicone rubber for sealing exhaust systems, high-temperature flanges and heating equipment.

Curing depends on moisture in the air; low temperature and low humidity extend the cure time.

Related Products

More Structural & Sealant Adhesives Options

Need a formulation matched to your application?

We customise formulations by substrate, viscosity, cure speed and media resistance, and provide sample testing and technical selection support.

Custom Bonding Solutions

Need adhesive selection advice or sample testing?

Tell us about your application and our engineers will provide product recommendations, sample dispatch and technical support within 48 hours.

×